Яндекс пиксель

GOST 3306-88: Requirements for Corrugated Mesh and How to Interpret Them Correctly

Technical Standards and Quality Requirements for Crimped Meshes

The state standard GOST 3306-88 regulates the technical conditions for the production of corrugated and complex-corrugated meshes intended for screening coal, ores, oil shale, coke, sinter, crushed stone, and other bulk materials. When purchasing screening surfaces, specialists often encounter the specific terminology of the standard. Let us examine the key aspects of GOST and their practical interpretation.

Types of Crimping According to GOST

The standard divides meshes by weave design into three types:

  • Partially Corrugated (PC): the weft wires have a bend at the interweaving points, while the warp wires are straight. Most often used for medium-sized openings.
  • Corrugated (C): the warp and weft wires have a bend (crimp) at all intersection points. This is the classic design for most vibrating screens.
  • Complex-Corrugated / Crimped (CC): the warp and weft wires have additional bends on the sides of the opening. This design ensures rigid fixation of the openings when working with large-piece, heavy materials, preventing wire displacement and changes in screening geometry.

Limit Deviations of Mesh Sizes

GOST strictly regulates dimensional accuracy. The limit deviation of the arithmetic mean of the mesh opening side size from the nominal value must not exceed ±4% for fine meshes and ±3% for coarse ones. Violation of these tolerances by the manufacturer leads to instability of the fractional composition of the finished product at the output of the vibrating screen.

Requirements for Wire Quality and Defects

According to GOST 3306-88, meshes must be manufactured from high-carbon or alloy steel capable of withstanding alternating vibration loads. This requirement should be interpreted from the standpoint of operating conditions: for medium loads, standard steel grades are sufficient, whereas for heavy ore materials, wear-resistant high-carbon or patented wire is required. The wire surface must be free of cracks, hairline seams, and laps, since any defects under the influence of vibration become stress concentration points and lead to rapid destruction of the screen.

How to Correctly Draw Up a Technical Specification for Purchasing Screens

Correct interpretation of GOST 3306-88 standards allows you to accurately draw up a technical specification for a supplier and guarantees a predictable service life of screens at your enterprise.

Share :

Contact Us

Submit a request — our specialist will contact you within 1 business day and offer the optimal solution for your production
Request a Quote
Submit a request — our specialist will contact you within 1 business day and offer the optimal solution for your production